Top search terms:MTGL automatic integrated oil and gas burner serie河南快3走势图MTG automatic one - piece gas burner series河南快3走势图MTL automatic one - piece fuel burner seriesMTG/C blast furnace gas burnerMTG/D automatic large split type gas burner seriesMTG/F generator gas burnerMTG/J coke oven gas burner河南快3走势图MTG/N split high temperature gas burnerMTL/B automatic large split type light oil burnerLow NOx burner

Current position: Home > Product > MTG/C blast furnace gas burner
Manette MTG/C series bf gas burner

1-1.jpg

Product overview:

MTG/CSeries bf gas burners are designed and manufactured according to the combustion characteristics of bf gas and the relevant international and domestic standards. They can be widely used in steam boilers, hot water boilers and other industrial furnaces.

MTG/CSeries of bf gas burners gas valve sets, programmed controllers, damper actuators and other famous brands are used to ensure excellent burner performance, safety performance and reliable operation.

 

Characteristics of blast furnace gas burner:

In view of the characteristics of low calorific value, difficult ignition, easy deignition and slow reaction speed of blast furnace gas, the design and manufacture of the blast furnace gas burner adopts the three-stage combustion mode, namely, the three-stage combustion of high-calorific value fuel is ignited first(Such as natural gas, liquefied gas)And as a part of the constant open fire ignition gas(Auxiliary gas)The main coal gas is ignited after stable combustion. The inner part of the burner is arranged with a heat-resistant stable combustion chamber. The gas and air are mixed in the circular slit with swirl vane and then spurted out for combustion, ensuring combustion stability and sufficiency.

Adaptive fuel:600kcal/Nm3≤Gas calorific value<1100kcal/Nm3

According to the requirements of the corresponding parts of the transformation can be adapted250℃Below high temperature combustion air.

Technical parameters:

Model

Maximum output

Regulation mode

Blower power

With the boiler

KW

104kcal/h

KW

T/h

MTG70/C

850

73

Slide two-stage or proportional control

2.2

1

MTG140/C

1700

146

4

2

MTG280-1/C

2550

219

5.5

3

MTG280/C

3400

292

7.5

4

MTG420/C

5100

439

11

6

MTG560/C

6800

585

15

8

MTG700/C

8500

731

22

10

MTG1050/C

12750

1096

30

15

MTG1400/C

17000

1462

45

20

MTG1750/C

21250

1827

55

25

Note:

The gas consumption is the calorific value of blast furnace gas800kcal/Nm3Calculation.

In the elevation500mAbove, must be recalculated for wind and fan power.

 

The performance characteristics of:

l  Fully automatic operation, suitable for a wide range of power

l  Gas pressure level protection

l  Air pressure protection

l  Dual gas shut-off valve, gas valve group automatic leak detection

l  Safe flame monitoring and flameout protection control

l  Automatic prepurge and postpurge

l  The damper closes automatically when the burner stops

l  SiemensLMVElectronic proportional control system(optional)

l  The flue gas oxygen quantity feedback regulation, ADAPTS the fuel gas which the calorific value changes in certain scope, realizes the energy conservation(optional)

Installation dimensions

 

GT外形-1.jpg

 

Ordering instructions:

▲  The user shall provide the gas data to the supplier before ordering.

▲  Installation and commissioning personnel must undergo professional training.

▲  Must pay attention to the burner installation and related equipment in accordance with the relevant safety specifications.

▲  Due to the continuous development of technology, the data listed in this information are subject to change without notice.

 

Quality assurance and after-sales service:

▲  Our products within a year to implement three guarantees, life - long maintenance.

▲  Our product debugging, service to ensure that the first time to reach the user.

▲ Our products will have professional and technical personnel to implement the whole tracking service users.


 

Model

size(mm

L

L1

L2

L3

L4

D1

D2

D3

D4

H1

H2

H3

d1

d2

n

d

P

P1

P2

Q

Q1

Q2

S1

S2

R

MTG70/C

1650

420

470

200

250

400

430

530

600

750

505

100

50

150

12

18

310

210

260

260

160

210

65

70

Φ14

MTG140/C

1650

420

470

200

250

520

550

650

700

750

505

100

50

200

12

18

340

240

290

340

240

290

95

95

Φ14

MTG280/C

1800

635

540

260

260

750

780

880

920

1050

760

200

80

250

20

18

345

240

300

365

260

318

100

106

Φ14

MTG420/C

1840

635

540

260

300

820

840

880

920

1050

760

210

80

300

20

18

345

240

300

365

260

318

100

106

Φ14

MTG560/C

2370

990

600

340

300

1000

1030

1180

1250

1270

970

350

125

350

24

22

505

400

460

405

300

360

115

90

Φ14

MTG700/C

2370

990

600

340

300

1200

1230

1380

1450

1370

1070

350

150

400

32

22

448

368

408

488

408

448

150

136

Φ14

MTG1050/C

2330

990

700

340

300

1400

1430

1580

1650

1460

1250

350

150

500

32

22

475

375

425

600

500

550

85

110

Φ14

MTG1400/C

2780

1100

750

400

350

1600

1630

1780

1850

1695

1500

435

200

600

30

26

750

650

700

600

500

550

100

110

Φ14

MTG1750/C

3032

651

1003

560

350

1680

1780

1870

1940

1425

940

350

150

700

24

25

850

750

800

790

690

744

200

124

Φ14

Note:1. D2The size is the hole size of furnace.

2。To take overd1d2Grade of all flangesPN1。0,They are auxiliary gas and main gas inlet respectively.

 

 

 

 

 

Contact us
Hotline:13264314609

Tel:0510-85100000

Add:No。 51, hutai road, north hutai industrial park, wuxi city, jiangsu province

河南快3走势 河南快3走势 天津快乐十分走势图 河南快3 黑龙江快乐十分 天津快乐十分 极速3D彩票 千禧彩票是真的吗 黑龙江快乐十分走势图 云南快乐十分